Flow Control Valves essentials

Flow-control valves include simple orifices to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature.

The purpose of flow control in a hydraulic system is to regulate speed. All the devices discussed here control the speed of an actuator by regulating the flow rate. Flow rate also determines rate of energy transfer at any given pressure. The two are related in that the actuator force multiplied by the distance through which it moves (stroke) equals the work done on the load. The energy transferred must also equal the work done. Actuator speed determines the rate of energy transfer (i.e., horsepower), and speed is thus a function of flow rate.

Directional control, on the other hand, does not deal primarily with energy control, but rather with directing the energy transfer system to the proper place in the system at the proper time. Directional control valves can be thought of as fluid switches that make the desired "contacts." That is, they direct the high-energy input stream to the actuator inlet and provide a return path for the lower-energy oil.

It is of little consequence to control the energy transfer of the system through pressure and flow controls if the flow stream does not arrive at the right place at the right time. Thus, a secondary function of directional control devices might be defined as the timing of cycle events. Because fluid flow often can be throttled in directional-control valves, some measure of flow rate or pressure control can also be achieved with them.

Different types of flow measurement

Controlling flow of a fluid-power system does not necessarily mean regulating volume per unit of time from a valve. Flow rate can be specified three different ways, so it is important to be aware of how flow is to be specified or measured:

Volumetric flow rateQv, expressed in units of in.3/sec or min - or cc/sec or cc/min in SI metric measure - is used to calculate the linear speeds of piston rods or rotational speeds of motor shafts.

Weight flow rateQw, expressed in units of lb/sec or lb/min, is used to calculate power using English units of measure.

Mass flow rateQg, expressed in units of slugs/sec or slugs/min for English measure - or kg/sec or kg/min in SI metric measure - is used to calculate inertia forces during periods of acceleration and deceleration.

Because they control the quantity of fluid that flows through the valve per unit of time, the same control valves are used for all three types of flow rates.

Control of flow rate with valves

Eight types of flow-control valves are used most often in hydraulic circuits:

fig. 1. simple fixed orifice (a) and variable orifice (b) flow controls.
Fig. 1. Simple fixed orifice (a) and variable orifice (b) flow controls.

Orifices — A simple orifice in the line, Figure 1(a), is the most elementary method for controlling flow. (Note that this is also a basic pressure control device.) When used to control flow, the orifice is placed in series with the pump. An orifice can be a drilled hole in a fitting, in which case it is fixed; or it may be a calibrated needle valve, in which case it functions as a variable orifice, Figure 1(b). Both types are non-compensated flow-control devices.

fig. 2. flow regulator adjusts to variations in inlet and output pressures.
Fig. 2. Flow regulator adjusts to variations in inlet and output pressures.

Flow regulators — This device, Figure 2, which is slightly more sophisticated than a fixed orifice, consists of an orifice that senses flow rate as a pressure drop across the orifice; a compensating piston adjusts to variations in inlet and outlet pressures. This compensating ability provides closer control of flow rate under varying pressure conditions. Control accuracy may be 5%, possibly less with specially calibrated valves that operate around a given flow-rate point.

Bypass flow regulators — In this flow regulator, flow in excess of set flow rate returns to tank through a bypass port, Figure 3. Flow rate is controlled by throttling fluid across a variable orifice regulated by the compensator piston. The bypass flow regulator is more efficient than a standard flow regulator.

fig. 4. demand-compensated flow control bypasses full pump output to tank during idle portion of work cycle.
Fig. 4. Demand-compensated flow control bypasses full pump output to tank during idle portion of work cycle.

Demand-compensated flow controls — Flow controls can also bypass excess system flow to a secondary circuit, Figure 4. Fluid is routed at a controlled flow rate to the primary circuit, and bypass fluid can be used for work functions in secondary circuits without affecting the primary one. There must be flow to the primary circuit for this type of valve to function - if the primary circuit is blocked, the valve will cut off flow to the secondary circuit.

fig. 5. pressure-compensated, variable flow-control valve adjusts to varying inlet and load pressures.
Fig. 5. Pressure-compensated, variable flow-control valve adjusts to varying inlet and load pressures.

Pressure-compensated, variable flow valves — This flow control is equipped with an adjustable variable orifice placed in series with a compensator. The compensator automatically adjusts to varying inlet and load pressures, maintaining an essentially constant flow rate under these operating conditions to accuracy of 3% to 5%, Figure 5. Pressure-compensated, variable flow-control valves are available with integral reverse-flow check valves (which allow fluid to flow unrestricted in the opposite direction) and integral overload relief valves (which route fluid to tank when a maximum pressure is exceeded).

fig. 6. pressure- and temperature-compensated, variable flow-control valve adjusts the orifice size to offset changes in fluid viscosity.
Fig. 6. Pressure- and temperature-compensated, variable flow-control valve adjusts the orifice size to offset changes in fluid viscosity.

Pressure- and temperature-compensated, variable flow valves — Because the viscosity of hydraulic oil varies with temperature (as do the clearances between a valve's moving parts), output of a flow-control valve may tend to drift with temperature changes. To offset the effects of such temperature variations, temperature compensators adjust the control orifice openings to correct the effects of viscosity changes caused by temperature fluctuations of the fluid, Figure 6. This is done in combination with adjustments the control orifice for pressure changes as well.

Fig. 7. Priority valve supplies fluid at a set rate to a primary circuit.

Priority valves — A priority valve, Figure 7, is essentially a flow-control valve that supplies fluid at a set flow rate to the primary circuit, thus functioning as a pressure-compensated flow-control valve. Flow in excess of that required by the primary circuit bypasses to a secondary circuit at a pressure somewhat below that of the primary circuit. Should inlet or load pressure (or both) vary, the primary circuit has priority over the secondary - as far as supplying the design flow rate is concerned.

fig. 8. deceleration valve slows load by being gradually closed by action of cam mounted on cylinder load.
Fig. 8. Deceleration valve slows load by being gradually closed by action of cam mounted on cylinder load.

Deceleration valves — A deceleration valve, Figure 8, is a modified 2-way, spring-offset, cam actuated valve used for decelerating a load driven by a cylinder. A cam attached to the cylinder rod or load closes the valve gradually. This provides a variable orifice that gradually increases backpressure in the cylinder as the valve closes. Some deceleration valves are pressure-compensated.

 

Other flow controls

fig. 9. linear-type flow divider splits single input into two output flows.
Fig. 9. Linear-type flow divider splits single input into two output flows.

Flow dividers — A flow-divider valve is a form of pressure-compensated flow-control valve that receives one input flow and splits it into two output flows. The valve can deliver equal flows in each stream or, if necessary, a predetermined ratio of flows. The circuit in Figure 9 shows how a flow divider could be used to roughly synchronize two cylinders in a meter-in configuration.

fig. 10. flow dividers can be cascaded in series to control multiple actuator circuits.
Fig. 10. Flow dividers can be cascaded in series to control multiple actuator circuits.

Like all pressure- and flow-control devices, flow dividers operate over a narrow bandwidth rather than at one set point. Thus, flow variations in the secondary branches are likely. Therefore, precise actuator synchronization cannot be achieved with a flow-divider valve alone. Flow dividers can also be used in meter-out circuit configurations or cascaded - connected in series to control multiple actuator circuits, Figure 10.

Rotary flow dividers — Another technique for dividing one input flow into proportional, multiple-branch output flows is with a rotary flow divider. It consists of several hydraulic motors connected together mechanically by a common shaft. One input fluid stream is split into as many output streams as there are motor sections in the flow divider. Because all motor sections turn at the same speed, output stream flow rates are proportional and equal to the sum of displacements of all the motor sections. Rotary flow dividers can usually handle larger flows than flow divider valves.

The pressure drop across each motor section is relatively small because no energy is delivered to an external load, as is the usual case with a hydraulic motor. However, designers should be aware of pressure intensification generated by a rotary flow divider. If, for any reason, load pressure in one or more branches drops to some lower level or to zero, full differential pressure will be applied across the motor section in each particular branch. The sections thus pressurized will act as hydraulic motors and drive the remaining section(s) as pump(s). This results in higher (intensified) pressure in these circuits branches. When specifying rotary flow dividers, system designers must be careful to minimize the potential for pressure intensification. A pressure relief valve should be placed in any actuator fluid line where this condition may occur. Rotary flow dividers can also integrate multiple branch return flows into a single return flow.

Proportional flow-control valves

Proportional flow-control valves combine state-of-the-art hydraulic valve actuation with modern, sophisticated electronic control. These valves help simplify hydraulic circuitry by reducing the number of components a system may require while, at the same time, substantially increasing system accuracy and efficiency.

An electronically controlled, proportional flow-control valve modulates fluid flow in proportion to the input current it receives. The valves can easily control cylinders or smaller hydraulic motors in applications that require precise speed control or controlled acceleration or deceleration. Most proportional flow-control valves are pressure-compensated to minimize flow variations caused by changes in inlet or outlet pressure.

An electrohydraulic proportional valve consists of three main elements:

  • a pilot or proportional solenoid
  • a metering area (where the valve spool is located), and
  • an electronic position-feedback device, often an LVDT (linear variable differential transformer).

Valve operation begins when it receives a signal from an outside controlling device such as a computer, programmable logic controller (PLC), traditional logic relay, or potentiometer. The control device delivers analog electrical signals to the valve driver card, which, in turn, sends a current signal to the solenoid on the valve.

The electromechanical force on the spool causes it to shift, gradually opening a flow path from the pump to the actuator port. The greater the command input signal, the greater the current to the valve solenoid, and, thus, the higher the flow from the valve. The important feature of this proportional valve is that all elements are proportional; thus, any change in input current changes force signals proportionately as well as the distance the valve spool will shift, the size of the flow path, the amount of fluid flowing through the valve, and finally the speed at which the actuator moves.

As the spool shifts, its motion is detected and monitored very accurately by an LVDT or other type of position-feedback transducer. This signal is fed back to the driver card where it is continuously compared with the input signals from the controller. If the two differ, the driver adjusts spool position until the two signals match.

Pressure-compensated proportional flow-control valves are 2-port valves in which the main control orifice is adjusted electronically. Similar to conventional pressure-compensated flow-control valves, a pressure-compensated proportional flow-control valve maintains constant flow output by keeping the pressure drop constant across the main control orifice. The proportional valve, however, is different in that the control orifice is modified to work in conjunction with a stroke controlled solenoid.

fig. 11. circuit diagram for pressure-compensated flow-control valve.
Fig. 11. Circuit diagram for pressure-compensated flow-control valve.

In a 2-port, pressure-compensated proportional flow-control valve, an electrically adjustable control orifice is connected in series with a pressure reducing valve spool, known as a compensator, Figure 11. The compensator is located upstream of the main control orifice and is held open by a light spring. When there is no input signal to the solenoid, the light spring force holds the main control orifice closed. When the solenoid is energized, the solenoid pin acts directly on the control orifice, moving it downward against the spring to open the valve and allow oil to flow from port A to port B.

At the same time, the LVDT provides the necessary feedback to hold position. In this case, the LVDT provides feedback to maintain a very accurate orifice setting.

Pressure compensation is achieved by incorporating a pilot passage at the inlet of the valve that connects to one side of the compensator spool, A2. There is another pilot passage located near the outlet of the valve beyond the control orifice, and it is connected to the opposite side of the compensator spool, A3. A bias spring on this side of the spool keeps the compensator in the open position. Load-induced pressure at the outlet port — or pressure deviations at the inlet port - modulate the compensator spool to increase or decrease the pressure drop across the compensator's metering orifice. Acting as a pressure reducing valve, the compensator ensures that the main control orifice sees a constant pressure drop. When the pressure drop is constant, the flow remains constant.

The amplifier provides time controlled opening and closing of the orifice. For reverse free-flow, check valve C, built into the valve, provides a flow path from port B to A. Proportional flow-control valves are also available with either linear or progressive flow characteristics. The input signal range is the same for both. However, the progressive flow characteristic gives finer control at the beginning of orifice adjustment.

In case electrical power or feedback is lost, solenoid force drops to zero and the force exerted by the spring closes the orifice. When feedback wiring is connected incorrectly or damaged an LED indicates the malfunction on the amplifier card.

Proportional flow logic valves

Proportional flow-control logic valves are basically electrically adjustable flow controls that fit into a standard logic valve cavity. The cover and cartridge are assembled as a single unit, with the cover consisting of a proportional force solenoid and a pilot controller, Figure 12.

fig. 12. cross-sectional view of proportional flow logic valve.
Fig. 12. Cross-sectional view of proportional flow logic valve.

When an electrical signal is fed into an electronic amplifier, the solenoid and controller adjust the pilot pressure supplied from port A to change spool position. An LVDT then feeds back the position to the amplifier to maintain the desired orifice condition for flow from port A to port B. The proportional logic valve is available with either linear or progressive flow characteristics, and the valve drivers respond to voltage (0 to 10 Vdc) or current (0 to 20 mA) command signals. The typical valve amplifier card requires a 24-Vdc power supply.

Because the valve remains relatively unaffected by changes in system pressure, it can open and close the orifice in the same length of time. This maximum time can be changed on the amplifier card by adjusting a built-in ramp generator.

The amplifier can be used in several ways. An external electronic control can make the orifice remotely adjustable while maximum spool acceleration is still limited by this internal ramp; or a  switch can be added to turn the ramp on and off. In case of power failure, the element will return to its normally closed position.

Need A Quote?

We'll do our best to support your business growth.